SPEC SFS 1 Baseline Summary

097.LADDIS (Volume 7, Issue 1, March 1995)


Sun Microsystems, Inc.

SPARCstation/server 20 Model 71

Throughput:

     NFS             Average       
     Throughput      NFS           
     SPECnfs_A93     Response Time 
     Ops/Sec         Milliseconds  
     --------------- ------------- 
     99              15.9
     197             18.7
     300             21.9
     399             23.1
     501             24.9
     599             27.8
     702             30.5
     806             33.8
     908             39.1
     1005            43.6
     1026            48.0

SPEC SFS 1 Baseline Result:
   1026 SPECnfs_A93 Ops/Sec @ 48 msec ==> 103 SPECnfs_A93 Users

Server Hardware
CPU, Memory, & Power
Model Number: SPARCstation/server 20 Model 71
CPU: 75MHz SuperSPARC II
Number of CPUs: 1
Primary Cache: 20KBI+16KBD on chip
Secondary Cache: 1MB(I+D) off chip
Other Cache: None
Memory: 64MB
UPS: None
Other Hardware: Ethernet
Server Software
OS Version: Solaris 2.4
Other Software: None
File System: UFS

Load Generators(LGs)
Number of Load Generators: 10
Processes Per Load Generator: 4
Biod_Max_Reads: 2
Biod_Max_Writes: 2

Disk Subsystem & Filesystems (Full Configuration Follows)
# of Disk Controllers: 7
# of Disks: 22
# of File Systems: 23

Network Subsystem (Full Configuration Follows)
# of Net Controllers: 2
# of Networks: 5
Type of Network: Ethernet

Server Tuning (Also see Notes/Tuning below)
Buffer Cache Size: Dynamic
# of NFS Daemons: 64
Fileset Size: 6.5GB

Hardware Availability: Feb-95
Software Availability: Oct-94

License #: 6
Tested : Nov-94
By: Sun
Of: Mountain View, CA

Notes/Summary Of Tuning Parameters
The adb tool was used to enable UDP checksumming on the load generators.
adb -w /vmunix /dev/kmem
udp_cksum/W 1
udp_cksum?W 1
UDP checksums are enabled by default on the server running Solaris 2.x
maxusers=32 ufs_ninode=48000
ncsize=48000 bufhwm=24000
autoup=600 tune_t_fsflushr=600

Detailed Server Description
Network Subsystem
2 Sbus Quad Ethernet Controller (SQEC)
5 Etnernets(N01-N05): 2 LGs each

Disk Subsystem & Filesystems
Controller 01: FSBE Ethernet/SCSI Controller
Disk: Sun 535MB Contents: OS, swap
SPARCstorage Array=SSA, Fibre Channel SBus Card=FC25/S,
Fibre Channel Optical Module=FC25/OM
SSA #1: 20 Sun 1.05GB disks, 1 FC25/S, 1 FC25/OM and
6 SCSI-2 Host Adapter (HA) within SSA
ctl 02(OM1/HA1): Disks 01-04, F01-F04 ctl 03(OM1/HA2): Disks 05-08, F05-F08
ctl 04(OM1/HA3): Disks 09-11, F09-F11 ctl 05(OM1/HA4): Disks 12-14, F12-F14
ctl 06(OM1/HA5): Disks 15-17, F15-F17 ctl 07(OM1/HA6): Disks 18-20, F18-F20

Detailed Load Generator (LG) Description
Load Gen. Type Model # of CPUs RAM OS Compiler
LG1 SPARCstation 2 1 32MB SunOS4.1.3 /bin/cc
LG2 SPARCstation 10/40 1 48MB SunOS4.1.3 /bin/cc

Testbed Configuration
       Load Generator Load Generator         Target      
       Number         Type           Network Filesystems     Notes
       -------------- -------------- ------- --------------- -------------
       01/06          LG2/LG1        N01/N03 F01,F05,F09,F12 Default
       02/07          LG1/LG1        N01/N04 F15,F18,F02,F06 Default
       03/08          LG1/LG1        N02/N04 F10,F13,F16,F19 Default
       04/09          LG1/LG1        N02/N05 F03,F07,F11,F14 Default
       05/10          LG1/LG1        N03/N05 F17,F20,F04,F08 Default